1.Measurement
CO2 concentration,humidity,temperature,flow,leaf temperature,PAR(light intensity), atmospheric pressure Parameters which indicate Chlorophyll fluorescence intensity such as Fo,Fj,Fi,Fp.
2.Calculation concentration Fluorescence parameters:Fv,Fv/Fm,Vj,Mo,PIABS,Area,tFm,etc.
3.Control Function Control the flow automatically Control the PAR automatically Control the measuring time Open and close style system optional Manual or automatic measurement Control the action light
4.Graphic Function
5.Interface Function
6.Software Embedded flash memory chips Interface:32G SD card,USB2.0 Automatic firmware update Position machine software free of installation
7.Power Supply
8.Module Function
Technical Specification
1.CO2 Sensor l Range:0~1500ppm l Resolution:0.1ppm l Accuracy:average noise≤0.4ppm;maximum noise≤0.8ppm(CO2 constant)
l Response time:15s
2.Light Quantum Sensor l Spectrum:400~700nm Resolution:1μmolE/m2s Error:±5%
3.Leaf Temperature Sensor l Type:T thermocouple l Range:0.0~50.0℃ Resolution:0.1℃ Error:±0.3℃
4.Atmospheric Temperature Sensor l Type:Thermistor l Range:0~50℃ l Resolution:0.1℃
5.Flow Meter l Range:0.3~1.0L/min l Resolution:0.01L/min
6.Humidity Sensor l Range:0~90%RH l Resolution:0.1%
7.Host l Memory capacity:32G SD card;8MB flash chip l Interface:USB2.0 l Power supply:7.2V 10Ah,Li-ion rechargeable,7 to 9 hours battery life of one charge l Size:28.0×24.5×16.0cm l Weight:5.0kg
8.Fluorescent Probe l Type:YX handheld l Light source:blue LED,470nm l Range of light intensity:3500μmolE/m2s l Measuring time:1s~10s,adjustable l Fastest sampling speed:5μs Weight:200g Size:2.5×9×5cm
9.Optic-controlled Module Type:YX-LA Light type:red LED,blue LED Spectrum:630nm,470nm Type:made up of red and blue LED Range:0~3500μmolE/m2s Light-emitting area:3.0×7.5cm Size of lamp base:10×3.5×5.5 cm
l Size of power supply:12×8×4cm l Power supply:7.2V 10Ah,Li-ion rechargeable l Light intensity control:automatic
10.Leaf Chamber(choose any one) YXLC-5 (130×ø90mm) areatus leaf chamber
11.Operating Conditions
|